"""Config flow for NEC M-Series and ME-Series displays."""
import necme
import voluptuous as vol
from homeassistant import config_entries
from homeassistant.data_entry_flow import AbortFlow
from .const import CONF_CONTROLLER, CONF_MODEL, CONF_MONITOR_ID, CONF_SERIAL, DOMAIN
class NECMEConfigFlow(config_entries.ConfigFlow, domain=DOMAIN):
"""Configuration for for NEC M/ME-Series displays."""
VERSION = 1
def __init__(self) -> None:
"""Initialize flow."""
self._host: str = ""
self._monitor_id: int = 0
self._model: str | None = None
self._serial: str | None = None
async def async_step_user(self, input):
"""Handle manually adding the integration."""
if input is not None:
controller_host = input[CONF_CONTROLLER]
discovered = await self._async_discover(controller_host=controller_host)
self._host = discovered.host
self._monitor_id = discovered.monitor_id
self._model = discovered.model
self._serial = discovered.serial
await self.async_set_unique_id(discovered.config_entry_unique_id)
return self.async_create_entry(
title=f"NEC {discovered.model}",
data={
CONF_CONTROLLER: discovered.host,
CONF_MONITOR_ID: discovered.monitor_id,
CONF_MODEL: discovered.model,
CONF_SERIAL: discovered.serial,
},
)
return self.async_show_form(
step_id="user",
data_schema=vol.Schema(
{
vol.Required(
CONF_CONTROLLER, description="Controller hostname or IP address"
): str
}
),
)
async def _async_discover(self, controller_host):
try:
ctrl = await necme.Controller.connect_tcpip(controller_host)
except ConnectionError as err:
raise AbortFlow("cannot_connect") from err
try:
monitor = await ctrl.probe_open_one_monitor()
except ValueError as err:
raise AbortFlow("bad_protocol") from err
except necme.UnsupportedPropertyError as err:
raise AbortFlow("bad_protocol") from err
try:
model = await monitor.read_model_name()
except ValueError as err:
raise AbortFlow("bad_protocol") from err
try:
serial = await monitor.read_serial_no()
except ValueError as err:
raise AbortFlow("bad_protocol") from err
return ControllerMeta(
host=controller_host,
monitor_id=monitor.endpoint.raw,
model=model,
serial=serial,
)
class ControllerMeta:
"""Discovered metadata about a particular connected monitor."""
def __init__(self, host, monitor_id, model, serial):
"""Initialize."""
if len(monitor_id) != 1:
raise ValueError("monitor_id must be exactly one byte")
monitor_id_raw = monitor_id[0]
if monitor_id_raw < 0x41 or monitor_id_raw > 0xA4:
raise ValueError("invalid monitor_id")
monitor_id = monitor_id_raw - 0x40
self.host = host
self.monitor_id = monitor_id
self.model = model
self.serial = serial
@property
def config_entry_unique_id(self):
"""A unique ID to use to track this controller and monitor as a config entry."""
return f"{self.model}:{self.serial}"