In a very simple setup a boiler provides heat to one heating circuit. If heating activated
is on
, the boiler maintains the selected flow temperature
by regulating the burner and the heat pump.
Once the current flow temperature
exceeds the selected flow temperature
+ temperature hysteresis off
, the heating will stop until the current flow temperature
drops below the selected flow temperature
+ temperature hysteresis on
(which is typically a negative value).
Thus to activate the heating you will need to set heatingactivated
to on
and set an appropriate flowtemp
. The latter should be derived from the heating temperature setting
which can be set using the physical dial/control on the boiler. It should be considered as the maximum flow temperature. You can also use a lower flow temperature to maintain a constant room temperature once the initial heating is done.