Qualisys Realtime SDK for .Net
This is C# package with SDK and examples that can help Qualisys users connect and stream data from Qualisys Track Manager in realtime. This handles all kind of data that QTM can capture. This includes marker data, 6dof objects, user bones, analog, force and gaze vector settings and data.
- Use RTProtocol::DiscoverRTServers to find out which QTM servers that you can connect to on a network.
- Use RTProtocol::IsConnected method to check if a connection to QTM already exists.
- Use RTProtocol::Connect method to connect to QTM.
- Use RTProtocol::StreamFrames to setup streaming from QTM (this lets you decide what to stream).
- Use RTProtocol::ReceiveRTPacket to get data/event/error packets.
- Use RTProtocol::StreamFramesStop to stop streaming data.
- Use RTProtocol::Disconnect to disconnect.
Below is a c# console application example on how to discover all QTM servers on the network. Connect to localhost, stream 6DOF position+euler+residual data.
using System;
using System.Collections.Generic;
using System.Threading;
using QTMRealTimeSDK;
using QTMRealTimeSDK.Data;
namespace RTSDKExample
{
class Program
{
static void Main(string[] args)
{
Example example = new Example();
example.DiscoverQTMServers(4547);
Console.WriteLine("Press key to continue");
Console.ReadKey();
while (true)
{
example.HandleStreaming("127.0.0.1");
if (Console.KeyAvailable)
{
if (Console.ReadKey(false).Key == ConsoleKey.Escape)
break;
}
}
}
}
class Example
{
RTProtocol rtProtocol = new RTProtocol();
public List<DiscoveryResponse> DiscoverQTMServers(ushort discoveryPort)
{
if (rtProtocol.DiscoverRTServers(discoveryPort))
{
var discoveryResponses = rtProtocol.DiscoveryResponses;
foreach (var discoveryResponse in discoveryResponses)
{
Console.WriteLine("Host:{0,20}\tIP Address:{1,15}\tInfo Text:{2,20}\tCamera count:{3,3}", discoveryResponse.HostName, discoveryResponse.IpAddress, discoveryResponse.InfoText, discoveryResponse.CameraCount);
}
}
return null;
}
~Example()
{
if (rtProtocol.IsConnected())
{
rtProtocol.StreamFramesStop();
rtProtocol.Disconnect();
}
}
public void HandleStreaming(string ipAddress)
{
// Check if connection to QTM is possible
if (!rtProtocol.IsConnected())
{
if (!rtProtocol.Connect(ipAddress))
{
Console.WriteLine("QTM: Trying to connect");
Thread.Sleep(1000);
return;
}
Console.WriteLine("QTM: Connected");
}
// Check for available 6DOF data in the stream
if (rtProtocol.Settings6DOF == null)
{
if (!rtProtocol.Get6dSettings())
{
Console.WriteLine("QTM: Trying to get 6DOF settings");
Thread.Sleep(500);
return;
}
Console.WriteLine("QTM: 6DOF data available");
rtProtocol.StreamAllFrames(QTMRealTimeSDK.Data.ComponentType.Component6dEulerResidual);
Console.WriteLine("QTM: Starting to stream 6DOF data");
Thread.Sleep(500);
}
// Get RTPacket from stream
PacketType packetType;
rtProtocol.ReceiveRTPacket(out packetType, false);
// Handle data packet
if (packetType == PacketType.PacketData)
{
var sixDofData = rtProtocol.GetRTPacket().Get6DOFEulerResidualData();
if (sixDofData != null)
{
// Print out the available 6DOF data.
for (int body = 0; body < sixDofData.Count; body++)
{
var sixDofBody = sixDofData[body];
var bodySetting = rtProtocol.Settings6DOF.Bodies[body];
if (bodySetting.Enabled)
{
Console.WriteLine("Frame:{0:D5} Body:{1,20} X:{2,7:F1} Y:{3,7:F1} Z:{4,7:F1} First Angle:{5,7:F1} Second Angle:{6,7:F1} Third Angle:{7,7:F1} Residual:{8,7:F1}",
rtProtocol.GetRTPacket().Frame,
bodySetting.Name,
sixDofBody.Position.X, sixDofBody.Position.Y, sixDofBody.Position.Z,
sixDofBody.Rotation.First, sixDofBody.Rotation.Second, sixDofBody.Rotation.Third,
sixDofBody.Residual);
}
}
}
}
// Handle event packet
if (packetType == PacketType.PacketEvent)
{
// If an event comes from QTM then print it out
var qtmEvent = rtProtocol.GetRTPacket().GetEvent();
Console.WriteLine("{0}", qtmEvent);
}
}
}
}